/cmr/alert

当前显示英文原文,切换到「中文」可查看译文。

alert

An alert rule defines conditions and runs its actions on the CMR controller. Device rules select devices with labels. State alerts remain active while all configured state conditions match and run actions once when...


cmr/alert

Package: cmr Type: Directory

An alert rule defines conditions and runs its actions on the CMR controller. Device rules select devices with labels. State alerts remain active while all configured state conditions match and run actions once when they become active. They fire again only after their conditions stop matching and then match again. Event alerts run actions for each matching occurrence and never remain active or contribute to active-alert counters. A rule can contain multiple state conditions but at most one event condition. Most alerts apply per device; upgrade-job-done is a system event for a whole upgrade job. See CMR - Alert rules for conditions, actions, and alert scope.

FlagNameDescription
XdisabledAlert rule is disabled.
ArgumentTypeDescription
namestringName of the alert rule.
labelsobjectSelect the devices, by labels, that the alert rule applies to. Supports + and - signs as AND and AND NOT operators, respectively; if no sign is provided, the OR operator is used. When labels is not set, the rule applies to all connected devices (labels=all).
connectedboolState condition that matches whether the device is connected (yes) or disconnected (no). Default: no.
cpu-abovenumAlert when CPU load is above the given percent value (0..100); a value equal to the threshold also fires the rule. Default: unset.
cpu-belownumAlert when CPU load is below the given percent value (0..100); it fires only for values strictly below the threshold. Default: unset.
hdd-abovenumAlert when disk (HDD) load is above the given percent value (0..100); a value equal to the threshold also fires the rule. Default: unset.
hdd-belownumAlert when disk (HDD) load is below the given percent value (0..100); it fires only for values strictly below the threshold. Default: unset.
mem-abovenumAlert when RAM load is above the given percent value (0..100); a value equal to the threshold also fires the rule. Default: unset.
mem-belownumAlert when RAM load is below the given percent value (0..100); it fires only for values strictly below the threshold. Default: unset.
health-abovenumAlert when the health sensor named by health-value goes above the given value; a value equal to the threshold also fires the rule. Devices that do not report the sensor are ignored. Default: unset.
health-belownumAlert when the health sensor named by health-value goes below the given value; it fires only for values strictly below the threshold. Devices that do not report the sensor are ignored. Default: unset.
health-valuestringName of the health sensor to compare, matching a name from /system/health/print, for example cpu-temperature. Uses the [cpu-temperature] style placeholder in the action text.
interface-changealt { change: enum (any) , change: ubit (running, not-running, added, removed) }Alert on an interface state change: - any (default) - Any state change. - running - An interface's link comes up. - not-running - An interface's link goes down. - added - An interface is first seen. - removed - An interface is no longer seen. running and not-running follow the link state of the interface, not its admin state: enabling or disabling an interface with no connection does not fire, while an actual link loss or recovery does.
interface-typealt { type: enum (any) , type: ubit (ethernet, wifi, bridge) }Restrict interface-change alerts to one interface type: - any (default) - Interfaces of any type. - ethernet - Ethernet ports. - wifi - Wireless interfaces. - bridge - Bridge interfaces.
upgrade-availableboolAlert when a newer RouterOS version is available for the device. Default: no.
disconnected-more-thantimeAlert when a device has been disconnected for longer than the given time. Default: unset.
upgrade-job-donealt { cond: enum (yes) , cond: ubit (success, fail) }Alert when an upgrade job finishes; the rule fires once for the whole job, when the last device of the job is done: - yes (default) - Any outcome. - success - The job finished successfully. - fail - The job failed. A job that ends without installing an upgrade is treated as a failed job, so the yes and fail variants both fire.
upgrade-donealt { cond: enum (yes) , cond: ubit (success, fail) }Alert when the upgrade of a device finishes; the rule fires once for every device that finished its upgrade: - yes (default) - Any outcome. - success - The upgrade finished successfully. - fail - The upgrade failed. When no newer version is available for a device, its upgrade still finishes as a failure (the [upgrade-error] is no upgrade available), so the yes and fail variants both fire.
unpaired-device-connectedboolAlert when a device that is not paired to the controller connects. Default: no.
rebootedboolEvent condition that fires when the device unexpectedly reboots. Default: no.
log-topicsmulti { array-id, array-id, topic: super { ! , topic: enum } }Log topics to follow; prefix a topic with ! to exclude it. Together with log-regex, defines a log-message event condition. CMR automatically instructs the device to forward matching log messages.
log-regexstringMatch log messages against the given regular expression. Each message matching the configured topics and regular expression fires the actions without creating a persistent active alert.
action.logstringWrite a message to the log when the alert fires. The message may contain placeholders such as [device] or [cpu-usage], replaced with the values of the device that fired; an inapplicable placeholder is rendered as unknown.
action.log-topicsmulti { array-id, topic: enum }Log topics to write the message to. Default: cmr,info.
action.log-prefixstringPrefix for the log message. When set, the prefix is prepended to the message without a separator; when unset the message is written as it is.
action.scriptenumRun a named system script when the alert fires. The script must allow itself to run with reduced rights; otherwise the action fails with executing script ... from cmr failed ... (not enough permissions). Set the script's dont-require-permissions to yes.
action.script-varsmulti { array-id, script-var: string }List of variable names to make available to the action.script: each variable is filled with the value for the device that fired. For example device, identity, address, board, version become $device, $identity, and so on in the script. A name with a hyphen (for example cpu-usage) cannot be read as an ordinary script variable.
action.http-urlstringHTTP webhook URL to call when the alert fires. On a failed call the alert writes alert "<name>" HTTP action failed: <reason> to the cmr topic with warning severity and counts the failure in action-failures; the other actions still run.
action.http-methodenum (get | post | put | delete | head | patch)HTTP method used for the webhook: - get - post - put - delete - head - patch
action.http-bodystringHTTP request body sent to the webhook. Supports the same placeholders as the log message, substituted per device (for example [device] and [version]). No Content-Type header is added automatically; add one with action.http-headers when the receiver expects it, for example Content-Type: application/json for a JSON body.
action.http-headersmulti { header: string }Additional HTTP headers sent with the webhook, each as Header: value. The request also carries the controller's RouterOS <version> user-agent.
reset-on-disconnectenum (yes | no) { yes:0, no:-1 }Clear (reset) a state alert when the device disconnects, so a reconnecting device fires the rule again if it still matches: yes or no. Default: no (the state is kept across a disconnect). Event alerts have no persistent state to reset.
severityenum (critical | high | medium | low)Severity of the alert: - critical - high - medium (default) - low
categorymulti { array-id, category: enum }Categories assigned to the alert. The category is a grouping label: the server assigns one according to the rule's conditions (for example performance, availability, version, network, or logging), and it can be changed to any value.
Read-only ArgumentTypeDescription
devicesnumNumber of devices the alert rule matches (the devices selected by labels). When the rule covers all devices, this count includes the controller itself.
devices-onnumNumber of devices with an active state alert. Event occurrences do not add to this count.
firednumTotal number of times the alert has fired.